44 DOCR 070366-B
on
off
RS485-2 RS485-1
Figure 37: RS-485 Termination Jumper
The Termination Jumper is shown in the diagram on the left. To enable
termination place the jumper over the two upper pins next to the “on” label
on the board. To disable termination place the jumper in the off position on
the lower two pins.
J1
J2
Figure 38: RS-485 connector pin-out
RS-485 connector pin-out
RS-485 data format
Baud Rate Programmable, 2400/4800/9600/19200/38400, default = 19200
Data Bit 8
Stop Bit 1
Parity N/A
Contact Solectria for available 485 cables for daisy-chaining multiple inverters or connecting
them to a SolrenView data monitoring logger.
4.8.8 SolrenView External Monitoring
The PVI 3800TL, 5200TL, 6600TL and 7600TL inverters include an option for a SolrenView
external gateway. This device can be used for the purpose of webbased monitoring and data
logging.
From the inverter a user can congure and monitor the inverter using a human-machine interface
(HMI). This HMI consists of the LCD and four buttons.
The backside of SolrenView gateway provides connectivity to the data monitoring system.
Solectria Renewables’ SolrenView web-based data monitoring system can be interfaced using
Ethernet over twisted pair.