78 DOCR 070366-B
STANDARDS /
DIRECTIVES
PVI 3800TL PVI 5200TL PVI 6600TL PVI 7600TL
Electronics
protection rating
NEMA 4, IEC 60068-2-11 (Salt mist)
Safety UL 1741, CSA 22.2 No. 107-01
SW Approval UL 1998
Isolation Monitor
Interrupt (IMI)
NEC 690.35, UL1741 CRD
Unintentional
Islanding protection
IEEE 1547, IEEE 1547.1
EMC FCC part 15 A & B, ICES-003
AFCI UL1699B (Type 1), NEC 690 2014
WARRANTY PVI 3800TL PVI 5200TL PVI 6600TL PVI 7600TL
Standard warranty 10 years
Extended warranty By request (15 or 20 year options)
Simulated utility source Maximum time (sec) at 60Hz
before cessation of current to the
simulated utility
Voltage (V) Frequency (Hz)
< 50% V Rated (60 Hz) 0.16
50% V ≤ V > 88% V Rated (60 Hz) 2
110% V < V < 120% V Rated (60 Hz) 1
120% V ≤ V Rated (60 Hz) 0.16
Rated f > 60.5 0.16
Rated f > 59.3 0.16
Utility interconnection voltage and frequency trip limits and trip times for all models:
Trip limit and trip time accuracy for all models:
Voltage:
±1 V (L-L)
Frequency: ±0.01Hz
Time: 1%, but not less than 100ms