The DSP is very efcient at computing control and signal processing tasks. The DSP also
has built-in on-chip peripherals that include a Pulse Width Modulation (PWM) driver,
Analog to Digital (A/D) converters and other related features.
Active Cooling
The inverters come with blowers which activate as needed to keep the internal
components within preset temperature limits. These blowers are located under the air
intake hood of the inverter.
Housekeeping Transformer
The housekeeping transformer, located in the bottom left of the AC sub panel, is a voltage
conversion device that transforms 480VAC to 120VAC for use within the inverter.
Isolation Transformer
The inverter comes equipped with an integral isolation transformer (Figure 1-1, Rear
View). The isolation transformer is designed for class-leading inverter efciency.
Inductor
The inductor (Figure 1-1, Rear View) is used to lter the AC waveform generated by the
power module, effectively reducing high frequency noise.
AC Sub Panel
The AC landing, ltering and sense fusing takes place in the AC sub panel (Figure
1-4). The AC sub panel also includes the main load-rated transformer contactors, AC
disconnect, surge modules and the soft-start circuit.
Figure 1-4 AC Sub Panel
AC Disconnect
AC Surge Modules
Soft Start Contactor
AC Line Filter
Soft Start Resistors
Main Contactor
Soft Start and AC Sense Fuses
AC Landing Busbars (3)
AC Distribution PCB