PV Powered PVP260kW Informações Técnicas Página 55

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 54
41
PVP250kW & PVP260kW Inverter
Installation & Operation Manual
Adjustable Voltage Range
The inverter is factory calibrated to the voltage and frequency limits detailed in
Appendix
D - Limits, Fault Codes, Torque Values, and Wire Sizes
. These limits are adjustable and
can be set by PV Powered eld technicians.
4.7 DC Wiring
!
DANGER
Before proceeding with the DC wiring, conrm that the PV array has been
disconnected from the inverter using the external DC disconnect.
!
DANGER
Avant d’effectuer les branchements CC, assurez-vous que les piles PV sont
déconnectées de l’onduleur en utilisant le connecteur CC externe.
!
DANGER
Make sure the PV array polarity and voltage between the positive and
negative cables are correct before connecting the PV array cables to the DC
terminal block.
!
DANGER
Assurez-vous que la polarité et le voltage des câbles positifs et négatifs des
piles PV sont corrects avant de brancher les câbles des piles PV aux bornes
CC.
The three DC busbars, positive, negative and ground are located in the lower left of the
DC panel. Refer to Figure 4-14. The positive and negative bars are vertically mounted
and the ground bar is horizontally mounted at the bottom of the cabinet. The positive
and negative busbars have 32 rows of two 3/8” diameter holes spaced 1” apart vertically.
The ground bar has 12 rows of two 3/8” diameter holes spaced 1” apart. See
Appendix D
,
Table D-10 for wire sizing limits for inverters with an optional fused subcombiner.
DC Input Voltage
Calculate the maximum open circuit (no load) voltage for each series module connection.
FOR ALL TEMPERATURE CONDITIONS, THE OPEN CIRCUIT VOLTAGE FOR
EACH SERIES CONNECTION MUST BE LESS THAN OR EQUAL TO 600 VDC.
Contact PV Powered if you require assistance calculating the maximum DC input voltage
for your array at your specic location.
DC Inputs
Each DC input connection must be wired to deliver the same input voltage.
Vista de página 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 128 129

Comentários a estes Manuais

Sem comentários